>On Sat, Jan 04, 2003 at 09:52:54 -0800, R Parker wrote:
>> Maybe I'll find some time to experiment with the
>> dither shapes. What's the theory, concept or objective
>> of triangular vs shaped noise? 
>
>Shaped noise has theoretically worse SNR, but sounds better to humans.
>
>I think it makes sense to do the resampling before the dither though.

i see no other sensible way to do it. otherwise, we resampling with
less information than we could have, and that's a bad idea.

i just realized, though, that clamping the signal to the [-1,+1] range
needs to be done after, not before, dithering; the dither value might
take a sample value out of range.

--p


-------------------------------------------------------